Wireless command device

RF 95


  • Thermoplastic enclosure

  • Mounting details to EN 50047

  • sWave® wireless technology (SW868/SW915/SW917)

  • No power supply, no wiring and pipe laying required

  • Easy programming of receiver

  • Output signal can be individually configured at the receiver

Technical data

Applied standards

EN 60947-5-1, EN 61000-6-2, EN 61000-6-3, EN 301 489-1, EN 301 489-3, EN 300 220-1, EN 300 220-2

Enclosure

thermoplastic, glass-fibre reinforced, shockproof, self-extinguishing UL 94 V-0

Cover

thermoplastic, glass-fibre reinforced, shockproof, self-extinguishing UL 94 V-0

Tightening torque

enclosure mounting screws: 1.2 … 1.3 Nm
cover screws: 0.5 … 0.6 Nm

Degree of protection

IP65/IP67 (IEC/EN 60529)

Voltage source

electrodynamic energy generator

Operation cycles

max. 12000 telegrams with repetitions/h

Ambient temperature

–20 °C … +65 °C

Wireless range

LR SW868/915/917:
max. 450 m outdoors,
max. 40 m indoors
ULR SW 868/915/917:
max. 700 m outdoors,
max. 50 m indoors

Mechanical life

> 1 million operations

Actuating time

min. 80 ms

Note

no status signal available

Wireless approvals

Europe: RED 2014/53/EU
USA: FCC - XK5-RF95SW915SR, XK5-RF95SW915LR
Canada: IC - 5158A-RF95SW915SR, 5158A-RF95SW915LR
Mexico: IFT - RCPSTRF17-1885, RCPSTRF17-1884
Brazil: ANATEL 04580-18-06718