RF IS M30 nb-ST

Note
  • 2 mounting nuts are included in delivery

Technical data

Applied standards EN 60947-5-2
Enclosure brass, nickeled
Actuator steel plate 45 x 45 x 1 mm, FE 360
Front cap PVC, black
Back cap PVC, black
Degree of protection IP 67 to IEC/EN 60529
Connection Coupling M12 x 1, 4-pole
Cable length 0.5 m, 1 m or 2 m
Ambient temperature –25 °C … +70 °C
Rated operating isolation voltage Ui 75 VDC
Rated operating current Ie 0.2 mA
Rated operating voltage Ue 3 … 5 VDC
Switching distances sn 15 mm; sa 0 … 12.15 mm;
sr 13.5 mm … 16.5 mm
Hysteresis approx. 10 %
Repeatability ≤ 5 %
Type of installation non-flush
Switching frequency see RF 96 ST / RF I/O
Correction factors Steel (Fe360) = 1; Stainless steel approx. 0.7; Brass approx. 0.5; Aluminium approx. 0.4; Copper approx. 0.4
Note The sensor may only be used in combination with RF 96 ST or RF I/O

Ordering details

Type   Material no.  
Type    Material no.   
RF IS M30 nb-ST 0.5 m 1260490
Type    Material no.   
RF IS M30 nb-ST 1 m 1228548
Type    Material no.   
RF IS M30 nb-ST 2 m stock type Standard versions, in stock or available at short notice 1189976
If you cannot find the version you require, just ask us! Our product portfolio to date has included many customised switchgear variants.