Safety sensor
RC Si M30 IP69 Extreme
Version with higher degree of protection IP69: suitable for cleaning with 80 °C hot water at 100 bar pressure at a distance of 100 mm from different directions
Stainless steel enclosure
Suitable for the food processing industry
Long life
Reed contacts, coded
Actuation from front
Switching distance up to 10 mm
With pre-wired cable
2 mounting nuts are included in delivery
The actuator is not included in the delivery of the switches
Technical data
General technical data
Applied standards
EN ISO 13849-1, EN ISO 14119, EN 60947-5-2, EN 60947-5-3*
Enclosure
stainless steel 1.4539
Defined object
MC 30 Niro
Sensor type
type 4 interlocking device
Coding level
low coding
Tightening torque
mounting nut: max. 75 Nm
Degree of protection
IP66, IP67, IP69 (IEC/EN 60529) / IP69K (ISO 20653)
Switching system
reed contacts
Switching elements
1 NC/1 NO contact or 2 NC contacts
Connection
cable 4 x AWG 20
Cable cross-section
4 x 0.56 mm²
Cable length
2, 5 or 10 m
Switching voltage
max. 30 VDC
Rated operating current/voltage Ie/Ue
max. 157 mA, with LED: max. 20 mA / 24 VDC
Utilisation category
DC-12
Voltage drop at Ie
3.15 V, with LED: 3 V
Short-circuit current Ik
switching contacts: max. 750 mA for 50 ms
LED: max. 30 mA for 50 ms
Degree of pollution
3
Safety class
II
Rated switching distance sn
10 mm
Assured switching distance »ON« sao
8 mm
Assured switching distance »OFF« sar
30 mm
Repeatability
± 0.5 mm
Hysteresis
approx. 14 mm
Ambient temperature
–20 °C … +85 °C
Mechanical life
> 10 million operations
Approvals
d
< on request
Safety-relevant data
EN ISO 13849-1
Performance Level PL e
Category
4
B10d (10 % load)
20 million
TM
max. 20 years
MTTFd
> 100 years
DC/DCavg
> 99 %
hop
8 h/day
dop
220 days/year
tzyklus
20 s
Note
The safety-related data are only valid in combination with a safety module, e.g. SRM 21 RT2 (mat. no. 1179203).
Downloads
Variants / Options
The following variants / options are available on request:
Maritime certification to DNV <