BZ 16-12F IP69 Extreme

Safety sensor Extreme
Material number: 1355627
  • Version with higher degree of protection IP69: suitable for cleaning with 80 °C hot water at 100 bar pressure at a distance of 100 mm from different directions
  • Thermoplastic enclosure
  • Long life
  • Differential inputs: Induction / magnetic operating principle
  • Internal monitoring, high manipulation protection
  • Potential-free outputs
  • Signalling contact
  • Status LED
  • 1 NO/2 NC contacts
  • Actuating plane: actuating from the front "F"
  • Rated switching distance sn = 12 mm
  • Wiring compartment
  • Attention: Please state required international approvals with your order!
Notes
  • The actuator is not included in the delivery of the switches
  • 1 cable gland M20x1.5 - IP69 and 2 locking screws M20x1.5 included in delivery
Contact

Technical data

Applied standards EN 61000-6-1, EN 61000-6-2, EN 61000-6-3, EN 61000-6-4, EN 60947-5-2, EN 60947-5-3, EN ISO 14119, EN 60204-1, EN ISO 13849-1, EN 62061, 2004/108/EG
Enclosure thermoplastic, glass-fibre reinforced, impact resistant, self-extinguishing UL 94 V-0
Sensor type type 4 interlocking device
Coding level low coding
Tightening torque enclosure mounting screws: max. 2 Nm
cover screws: max. 1.5 Nm
actuator screws: max. 2 Nm
Degree of protection IP 69 (IEC/EN 60529)
Safety-relevant data:
EN ISO 13849-1 Performance Level PL e
Category 3
B10d (10 % load) 20 million
TM max. 20 years
MTTFd 100 years
DC/DCavg 96 %
EN 62061 SIL CL 3
PFHd ≥ 4.29 x 10-8 1/h
hop 8 h/day
dop 220 days/year
tzyklus 20 s
Switching distances sn = 12 mm (10 mm with flush mounting)
sao = 10 mm (8 mm with flush mounting)
sar = 25 mm
(Minimum distance 2 mm for approach from side.)
Hysteresis approx. 6 mm
Sideways tolerance ≤ 3 mm
Repeatability ± 1 mm
Rated operating current/voltage Ie/Ue 140 mA/24 VDC ± 15 %
(reverse voltage protected);
output contacts: max. 3 A/24 VAC/DC, min. 10 mA/5 VAC/DC;
signalling contact: max. 1 A/24 VAC/DC, min. 100 μA/100 mVDC
No-load supply current I0 ≤ 70 mA
Short-circuit protection Ue: 0.25 A (slow blow);
output contacts: 4 A (gG/gN) incoming series-connected
Outputs 2 enabling paths (1 NO/1 NC)
1 signalling contact (1 NC)
Switching voltage max. 30 VAC/DC
Conditional short-circuit current 100 A
Utilisation category AC-15; DC-13 (output contacts)
AC-12; DC-12 (signalling contact)
Rated operating isolation voltage Ui 250 VAC
Rated impulse withstand voltage Uimp 1.5 kV
Voltage drop at Ie max. 0.6 V
Overvoltage category III
Switching frequency max. 1 Hz
Attendance delay tv < 300 ms
Risk time max. 165 ms
Degree of pollution 3
Ambient temperature 0 °C … +55 °C
Storage and shipping temperature –20 °C … +70 °C
Mechanical life 50 mio. operations
Contact material output contacts: AgSnO self-cleaning, positive-guided; signalling contact: AgNi, gold-plated
Contact resistance output contacts: 100 mΩ in new condition; signalling contact: max. 30 mΩ
Connection wiring compartment with socket screw clamps 8-pole
Cable entry 3 x M20 x 1.5
Cable cross-section min. 0.14 mm² / AWG 28
max. 1.5 mm² / AWG 16
Approvals
Note The safety-related data are based on a load of 24 V / 0.1 A / DC-1 for the enabling paths. With higher load currents for the enabling paths and other requirement rates nop, the safety-related data vary from the given data and can be provided on request.

Contact diagram

Monitoring of antivalence required

Actuating planes

Axial misalignment

Approach from side


Actuators

Type   Material no.  
Type    Material no.   
Actuating magnet coded BZ 16-B1 stock type Standard versions, in stock or available at short notice 1165032