RF RC M30
Wireless magnetic sensor
- Thermoplastic or stainless steel enclosure
- Power supply: Lithium battery
- sWave® wireless technology
Applied standards | EN 60947-5-1, EN 60079-0, EN 60079-1, EN 60079-31, EN ISO 13849-1, EN ISO 14119 |
---|---|
Enclosure | thermoplastic, glass-fibre reinforced, impact resistant, self-extinguishing UL 94 V-0 |
Cover | steel, enamel finish |
Switch type | type 1 |
Coding level | no coding |
Degree of protection | IP 65 to IEC/EN 60529 |
B10d (10 % load) | 2 million |
TM | max. 20 years |
Switch insert | 1 x Ex 13 |
Contact material | silver |
Switching system | slow action, positive break NC contacts ![]() |
Switching elements | 1 NC/1 NO contact, type Zb |
Connection | pre-wired cable H05VV-F |
Cable cross-section | 4 x 0.75 mm² (incl. conductor ferrules) |
Cable length | 2 or 5 m |
Rated impulse withstand voltage Uimp | 4 kV |
Rated insulation voltage Ui | 250 V |
Conventional thermal current Ithe | T6: 6 A, T5: 3 A |
Rated operating current/voltage Ie/Ue | 6 A/250 VAC; 0.25 A/230 VDC |
Utilisation category | AC-15; DC-13 |
Short-circuit protection | 6 A gG/gN fuse |
Ambient temperature | T6: –20 °C … +65 °C, T5: –20 °C … +75 °C, +90 °C with max. 3 A |
Mechanical life | > 1 million operations |
Operation cycles | max. 1800/h |
Repeat accuracy of switching points | ± 0.1 mm |
Contact opening | max. 2 x 4.5 mm |
Impact energy | max. 7 J |
Ex marking | ![]() ![]() T80 °C/T95 °C Db IECEx Ex db IIC T6/T5 Gb, Ex tb IIIC T80 °C/T95 °C Db |
Approvals | PTB 03 ATEX 1068 X * IECEx PTB 06.0053X * ![]() ![]() ![]() |
Roller plunger R, * with safety function
Ex T 356 R 1Ö/1S-2m * | 1173048 | ||
Ex T 356 R 1Ö/1S-5m * | 1174034 | ||
Rocking lever 4VH, * with safety function
Ex T 356 4VH 1Ö/1S-2m * | 1173059 | ||
Ex T 356 4VH 1Ö/1S-5m * | 1173060 | ||
Adjustable rocking lever 4V7H-2138, * with safety function
Ex T 356 4V7H 1Ö/1S-2138-2m * | 1179068 | ||
Ex T 356 4V7H 1Ö/1S-2138-5m * | 1179361 | ||