RF RC M30
Wireless magnetic sensor
- Thermoplastic or stainless steel enclosure
- Power supply: Lithium battery
- sWave® wireless technology
Applied standards | EN 60947-5-1, EN 60079-0, EN 60079-1, EN 60079-31, EN ISO 13849-1 |
---|---|
Enclosure | aluminium die-cast, powder-coated |
Pedal | thermoplastic, glass-fibre reinforced, impact resistant, self-extinguishing UL 94 V-0 |
Protective shield | aluminium die-cast, powder-coated |
Degree of protection | IP 65 to IEC/EN 60529 |
B10d (10 % load) | Ex GFS 3: 2 million |
TM | Ex GFS 3: max. 20 years |
Connection | pre-wired cable H05VV-F |
Cable cross-section | 3 or 4 x 0.75 mm² (incl. conductor ferrules) |
Cable length | 3 m |
Contact material | silver |
Switching system | Ex GFS: slow action, positive break NC contacts ![]() Ex GFSM: snap action |
Switching elements | Ex GFS: 1 NC/1 NO contact, type Zb Ex GFSM: change-over contact with single break C or 1 NC/1 NO contact, type Za |
Switch insert | Ex GFS: Ex 14 Ex GFSM: type C: ExM 14, type Za: ExM 14 1Ö/1S |
Utilisation category | AC-15; DC-13 |
Rated operating current/voltage Ie/Ue | Ex GFS 3: 6 A/250 VAC; Ex GFSM 3: 5 A/250 VAC; Ex GFSM 3 1ÖS/1ÖS/1ÖS: 5 A/250 VAC; |
Short-circuit protection | Ex GFS 3: 6 A gG/gN fuse Ex GFSM 3: 5 A gG/gN fuse |
Ambient temperature | T6: –20 °C … +60 °C, T5: -20 °C … +75 °C |
Mechanical life | > 1 million operations |
Impact energy | max. 7 J |
Ex marking | ![]() ![]() T80 °C/T95 °C Db IP65 IECEx Ex d IIC T6/T5 Gb, Ex tb IIIC T80 °C/T95 °C Db IP65 |
Approvals | PTB 11 ATEX 1002 X IECEx PTB 11.0090X * ![]() ![]() ![]() * depending on the variant (see » Certificates) |
Snap action, 1 NC/1 NO contact per pedal
Ex GFSM 3 1ÖS/1ÖS/1ÖS - 3m | on request Produced to order. | ||
If you cannot find the version you require, just ask us! Our product portfolio to date has included many customised switchgear variants. |