Ex emergency pull-wire switch

Ex ZS 75 S Mining


  • Device group I (Mining)

  • Equipment category M2

  • Metal enclosure

  • 2 contacts

  • Wire length up to 2 x 100 m

Technical data

Applied standards

EN 60947-5-5, EN ISO 13849-1, EN IEC 60079-0, EN 60079-1, EN IEC 60079-7, EN 60079-11, EN 50303

Enclosure

zinc die-cast, enamel finish

Cover

zinc die-cast, enamel finish

Degree of protection

IP65 (IEC/EN 60529)

B10d (10 % load)

300 000

TM

max. 20 years

Contact material

silver

Switching system

slow action, positive break NC contacts A

Switching elements

2 NC contacts

Connection

screw connection terminals

Cable cross-section

max. 1.5 mm² (incl. conductor ferrules)

Cable entry

2 x M20 x 1.5

Clamping range

6 … 12 mm

Rated impulse withstand voltage Uimp

4 kV

Rated insulation voltage Ui

250 V

Conventional thermal current Ithe

6 A

Rated operating current/voltage Ie/Ue

6 A/250 VAC; 0.25 A/230 VDC

Utilisation category

AC-15; DC-13

Short-circuit protection

6 A gG/gN fuse

Ambient temperature

–20 °C … +60 °C

Mechanical life

> 150 000 operations

Max. wire length

2 x 100 m

Ex marking

L I M2 Ex db eb I Mb

Approvals

OBAC 10 ATEX 264X

Downloads

Loading...
Mounting and wiring instructions – Ex ZS 75 Mining

German, English, French, Italian, Portuguese

PDF 3 MB 18.12.2023
Please go to the relevant product pages for additional downloads.
Loading...