RF RC M30
Wireless magnetic sensor
- Thermoplastic or stainless steel enclosure
- Power supply: Lithium battery
- sWave® wireless technology
Applied standards | EN 60947-5-1, EN 60079-0, EN 60079-1, EN 60079-7, EN 60079-31, EN ISO 13849-1 |
---|---|
Enclosure | aluminium die-cast, corrosion-resistant, powder-coated, anthracite grey, similar to RAL 7016 |
Cover | stainless steel 1.4401, powder-coated, signal yellow, similar to RAL 1003 |
Sealing | silicone |
Degree of protection | IP 66 to IEC/EN 60529 |
B10d (10 % load) | 2 million |
TM | max. 20 years |
Contact material | silver |
Switching system | slow or snap action |
Switching elements | 1 NC/1 NO contact or 2 NC contacts, type Zb |
Connection | screw connection terminals |
Cable cross-section | min. 0,75 mm² / AWG 18, max. 1,5 mm² / AWG 16, incl. conductor ferrules |
Cable entry | 1 x M20 x 1.5 (incl. 1 cable gland) |
Clamping range | 7 … 13 mm |
Rated impulse withstand voltage Uimp | 4 kV |
Rated insulation voltage Ui | 250 V |
Rated operating current Ie | max. 4.4 A T6 / max. 6.6 A T5 |
Rated operating voltage Ue | max. 250 VAC; 125 VDC |
Utilisation category | AC-15; DC-13 |
Short-circuit protection | 4 A / 6 A gG/gN fuse |
Ambient temperature | T6: -40° C … +70° C (max. 4.4 A) T5: -40° C … +70° C (max. 6.6 A) |
Mechanical life | > 1 million operations |
Operation cycles | max. 1800/h |
Repeat accuracy of switching points | ± 0.1 mm |
Impact energy | max. 7 J |
Ex marking | ![]() ![]() T80°C/T95°C Db IECEx Ex db eb IIC T6/T5 Gb, Ex tb IIIC T80°C/T95°C Db |
Approvals | DMT 01 ATEX E 178 IECEx BVS 07.0014 ![]() ![]() ![]() ![]() |
Slow action, 1 NC/1 NO contact
Ex ES 98 SR-11 -40°C | stock type Standard versions, in stock or available at short notice | 1420735 | |
Slow action, 2 NC contacts
Ex ES 98 SR-02 -40°C | stock type Standard versions, in stock or available at short notice | 1420738 | |
Snap action, 1 NC/1 NO contact
Ex EM 98 SR-11 -40°C | stock type Standard versions, in stock or available at short notice | 1443731 | |