Safety sensor

RC Si 56


  • Thermoplastic enclosure

  • Long life

  • Reed contacts, coded

  • Actuation from front

  • Switching distance up to 6 mm

  • With pre-wired cable

Notes
  • The actuator is not included in the delivery of the switches

Technical data

Applied standards

EN 60947-5-1, EN 60947-5-3, EN ISO 13849-1, EN ISO 14119

Enclosure

thermoplastic, glass-fibre reinforced, shockproof, self-extinguishing UL 94 V-0

Defined object

MC 56, MC 56-3

Sensor type

type 4 interlocking device

Coding level

low coding

Degree of protection

IP67 (IEC/EN 60529)

Switching system

reed contacts

Switching elements

1 NC/1 NO contact or 2 NC contacts

Connection

pre-wired cable 4 x AWG 24

Switching voltage

max. 30 VDC

Rated operating current/voltage Ie/Ue

max. 157 mA, with LED: max. 20 mA / 24 VDC

Utilisation category

DC-12

Voltage drop at Ie

3.15 V, with LED: 3 V

Short-circuit current Ik

switching contacts: max. 750 mA for 50 ms
LED: max. 30 mA for 50 ms

Assured switching distance »OFF« sar 

> 23 mm

Repeatability

± 0.5 mm

Hysteresis

min. 23 mm

Degree of pollution

3

Safety class

II

Ambient temperature

–20 °C … +85 °C

Mechanical life

> 1 million operations

Approvals

< on request

EN ISO 13849-1

Performance Level PL e

Category

4

B10d (10 % load)

2 million

TM

max. 20 years

MTTFd

> 100 years

DC/DCavg

> 99 %

Note

The safety-related data are only valid in combination with a safety module, e.g. SRM 21 RT2 (mat. no. 1179203).
 

Downloads

Loading...
Mounting and wiring instructions – RC Si 56

German, English, French, Italian, Portuguese, Russian

PDF 4 MB 19.09.2023
Please go to the relevant product pages for additional downloads.
Loading...

Other interesting products

Alternative version with explosion protection

Ex Safety

Version with higher degree of protection

Safety