HS 98 with analogue output

  • With analogue output
  • Design to EN 50041
  • Wiring compartment
  • High degree of protection IP 67

Technical data

StandardsEN 60947-5-2; EN 60947-5-7
Enclosurealuminium die-cast, powder-coated
Degree of protectionIP 67 to IEC/EN 60529
Switching systemHall sensor with analogue output
Linearity2 %
ConnectionCage clamps
Cable cross-sectionmax. 0.08 … 2.5 mm², AWG 28 … 12
Cable entry1 x M20 x 1.5
Over temperature protectionmonitoring via μ controller + NTC
Rated operating voltage Ue24 VDC
Operating voltage range18-30 VDC
Rated output currentIB (Q2) ≤ 100 mA short-circuit protected
Rated output voltageUB (Q2) ≤ Ue - 2 V min.
 
Variants with output current
Ie≤ 135 mA at max. output current (Q1+Q2)
Rated output currentIB (Q1) (0) 4 … 20 mA; max. 20.4 mA
Working resistance≤ 400 Ω
 
Variants with output voltage
Ie≤ 25 mA
Rated output voltageUB (Q1) 0 … 10 V; max. 10.2 V
Working resistance≥ 1 kΩ
 
Attendance delay tv≤ 0.5 s
Max. fuse ratinginternal fuse 0.375 mA F
Ambient temperature–20 °C … +60 °C
Mechanical life> 1 million operations

Ordering details

Roller plunger R

Type   Material no.  
Type    Material no.   
HS 98 R 4-20 mA 1355834
If you cannot find the version you require, just ask us! Our product portfolio to date has included many customised switchgear variants.