Safety relay module SRM 21 RT2

Features/Options

  • Enclosure width: 22.5 mm
  • 2 NC or 1 NC/1 NO contact can be connected
  • Feedback circuit
  • 2 enabling paths
  • 1 transistor output
  • Manual or automatic reset
  • LED indicator for switching condition
  • Crossed wire monitoring

Technical data

StandardsEN ISO 13849-1; EN 62061;
EN 60204-1, BG-GS-ET 20;
EN 60947-5-1, -3; EN 61326-3-1
Enclosureblack polycarbonate; polyamide terminal clamps V0
Contact materialAgNi 10 + 0.2 µm Au
MountingDIN rail mounting
Connectionscrew terminals
with + and - screws
Cable cross-sectionmin. 1x 0.5 mm² (AWG 20)
including conductor ferrules,
max. 1x 2.5 mm² (AWG 14) including conductor ferrules,
2x 1.5 mm² (AWG 16) including conductor ferrules
Degree of protectionEnclosure IP 40, Terminal block
IP 20 to IEC/EN 60529,
shock protection to VBG 4
 
Safety-relevant data:*
EN 60204-1stop category 0
EN 62061SIL CL 3
PFHd3 x 10-8 1/h
EN ISO 13849-1PL e, Category 4
Safety requirements nop
hop8 h/day
dop220 days/year
tzyklus30 s
TMmax. 20 years
MTTFd> 86 years
DC/DCavg> 99 %
 
Rated operating voltage Ue24 VDC ±15 %
Rated operating current Ie0.125 A
Rated operating isolation voltage Ui250 VAC
Rated impulse withstand voltage Uimp4 kV
Conditional short-circuit current100 A
Inputs1 NC/1 NO contact or 2 NC contacts,
1 feedback circuit, 1 start input (monitored)
Outputs2 enabling paths, 1 transistor output as signalling output
Ie/Ue enabling paths3 A/230 VAC; 2 A/24 VDC
Utilisation categoryAC-15; DC-13
Contact load capacitymin. 10 mA
Typ. input current/
voltage
22 mA/ 20 VDC
Max. load of signalling output20 mA
Max. fuse ratingpower supply 2A slow blow, enabling paths 6 A gG/gN fuse
Delay on energisation/ deenergisation≤ 20 ms
Risk time≤ 0.5 s (switch-on delay)
Mechanical life> 50 million operations
Display1 LED for supply voltage, 1 LED each for input A and B, 1 LED for authorisation
Degree of pollution2
Overvoltage categoryIII
Ambient temperature–25 °C … +50 °C
Storage and shipping temperature–25 °C … +70 °C
Relative humidity10 % ... 90 %
Shock resistance3 g
Approvals
NoteInductive loads (contactors, relays etc.) are to be suppressed by suitable circuitry.
Weight220 g
Ordering details
Type code
Type   Material no.
Safety relay module SRM 21 RT2 stock type Standard versions, in stock or available at short notice 1179203
If you cannot find the version you require, just ask us! Our product portfolio to date has included many customised switchgear variants.