RC Si 56 IP69K Extreme

Features/Options

  • Thermoplastic enclosure
  • Long life
  • Reed contacts, coded
  • Actuation from front
  • Switching distance up to 6 mm
  • With pre-wired cable
  • Version with LED lamp available on request
  • Version with higher degree of protection IP 69K: suitable for cleaning with 80 °C hot water at 100 bar pressure at a distance of 100 mm from different directions
Note
  • The actuator is not included in the delivery of the switches

Product image

 

Technical data

StandardsEN ISO 13849-1;
EN 60947-5-2;
EN 60947-5-3/PDF-M*;
EN 954-1; EN 1088
Enclosureglass-fibre reinforced thermoplastic, self-extinguishing
ActuatorMC 56
Degree of protectionIP 69K to DIN 40050-9
Switching systemreed contacts
Switching elements1 NC/1 NO contact or 2 NC contacts
Connectionpre-wired cable 4 x AWG 24
B10d (10 % Load)1 million
TMmax. 20 years
MTTFd> 100 years
Uemax. 30 VDC
Iemax. 157 mA DC, with LED: max. 20 mA DC
Voltage drop at Imax3.15 V, with LED: 3 V
Short-circuit currentmax. 750 mA for 50 ms, with LED: max. 30 mA for 50 ms
Switching frequencymax. 5 Hz
Safety classII
Ambient temperature–20 °C … +85 °C
Mechanical life> 10 million operations
Repeatability< 0.5 mm
Switching distances:
smax6 mm
sao4 mm
sar23 mm
Approvals
on request

* is only achieved in combination with a safety module