// EXPLOSION PROTECTION

EEx STM 295

Technical data

Standards: IEC/EN 60947-5-1; EN 1088;
EN 60079-0; EN 60079-15;
EN 61241-0; EN 61241-1
Enclosure glass-fibre reinforced, shock-resistant thermoplastic, self-extinguishing UL 94-V0
Actuator stainless steel 1.4301
Switch insert Ex 95
Protection class IP 67 according to EN 60529
Contact material silver
Switching system slow action, NC contact with positive break Zwangsöffnung
Switching elements 2 NC and 2 NO contacts with positive break, galvanically separated contact bridges
Connection M3 screw clamps
B10d(10% Load) 2 million
M 10 years
Cable section max. 1.5 mm2 (incl. conductor ferrules)
Cable entries 2 x M20 x 1.5 for cable section 5 … 9 mm
Cable length -
Uimp 4 kV
Ui 250 V
Ithe 4 A
Ie/Ue 4 A/250 VAC; 0.25 A/230 VDC
Utilisation category AC-15, DC-13
Max. fuse rating 6 A gL/gG D-fuse
Us 24 VDC
Magnet 100 % ED
Unlocking 100 % ED
Power consumption max. 47 W
Ambient temperature –20 °C … +55 °C
Mechanical life > 1 million operations
Holding force F max. 1000 N
Holding force of integrated ball catch -
Ex certification EEx geprüft II 3G Ex nR IIC T4,
II 3D Ex tD A22 IP67 T100°C
Approvals -

Contact variants

  Spring-to-lock principle  Power-to-lock principle 
2 NC/2 NO contact
EEx STM 295 2Ö/2S-R
EEx STM 295 2Ö/2S-A

    Actuating radius