EEx 95 AZ

Technical data

Standards IEC/EN 60947-5-1; EN 1088;
EN 50014; EN 50018; EN 50019;
EN 50281-1-1
Enclosure glass-fibre reinforced, shock-proof thermoplastic, self-extinguishing UL 94-V0
Actuator stainless steel 1.4301
Switch insert
Protection class IP 67 to EN 60529
Contact material silver
Switching system slow action, positive break NC contact Zwangsöffnung
Switching elements changeover contact Zb or 2 NC contacts, galvanically separated contact bridges
Termination M3 screw clamps
Cable section max. 1.5 mm 2 (incl. conductor ferrules)
Cable length -
Uimp 4 kV
Ui 250 V
Ithe 6 A
Ie/Ue 6 A/250 VAC; 0,25 A/230 VDC
Utilisation category AC-15, DC-13
Max. fuse rating 6 A gL / gG D-fuse
Positive break travel 9 mm
Positive break force -
Ambient temperature –20 °C … +60 °C
Mechanical life > 1 million operations
Ex certification EEx geprüft II 2G EEx d IIC T6, II 2D IP67 T80°C
Approvals DMT 01 ATEX E 118

Kontaktvarianten

  Slow action   
1 NC/1 NO contact
EEx 95 AZ 1Ö/1S
2 NC contacts
EEx 95 AZ 2Ö

    Actuating radius