| Standards | IEC/EN 60947-5-1; EN 1088; BG-GS-ET-15; EN 50 014; EN 50 018; EN 50 019; EN 50281-1-1 |
|---|---|
| Design | mounting details to |
| Enclosure | zinc die casting, enamelled |
| Switch insert | Ex 95 |
| Protection class | IP 67 according to IEC/EN 60529 |
| Contact material | silver |
| Switching system | slow action, positive break NC contacts ![]() |
| Switching elements | change-over contact with double break Zb or 2 NC contacts, galvanically separated contactbridges |
| Connection | M3 screw clamps |
| B10d(10% Load) | 2 million |
| M | 10 years |
| Cable section | max. 1.5 mm2 (incl. conductor ferrules) |
| Cable entry | M20 x 1.5 |
| Uimp | 4 kV |
| Ui | 250 V |
| Ithe | 6 A |
| Ie/Ue | 6 A/250 VAC; 0.25 A/230 VDC |
| Utilisation category | AC-15, DC-13 |
| Max. fuse rating | 6 A gL/gG D-fuse |
| Ambient temperature | –20 °C … +60 °C |
| Mechanical life | > 1 million operations |
| Ex certification | II 2G EEx de IIC T6,II 2D IP65 T80°C |
| Approvals | BVS 04 ATEX E 126 ![]() ![]() ![]() |
| Slow action | ||
|---|---|---|
| 1 NC/1 NO contact | EEx 355 V.S 1Ö/1S |
|
| 2 NC contacts | EEx 355 V.S 2Ö |