// EXPLOSION PROTECTION

EEX 335

Technical data

Standards IEC/EN 60947-5-1; EN 1088;
EN 50014; EN 50018; EN 50019;EN 50281-1-1
Design DIN EN 50 041
Enclosure zinc die-cast, enamelled
Switch insert Ex 95
Protection class IP 65 according to EN 60529
Contact material silver
Switching system slow action, positive break NC contact Zwangsöffnung
Switching elements change-over contact with double break Zb or 2 NC contacts, galvanically separated contact bridges
Termination M3 screw clamps
Cable section max. 1.5 mm2 (incl. conductor ferrules)
Cable length -
Uimp 4 kV
Ui 250 V
Ithe 6 A
Ie/Ue 6 A/400 VAC; 0.25 A/230 VDC
Utilisation category AC-15, DC-13
Max. fuse rating 6 A gL/gG D-fuse
Ambient temperature –20 °C … +60 ºC
Mechanical life > 1 million operations
Switching frequency 1800/h
Repeat accuracy ±0.1 mm
Contact gap max. 2 x 3.5 mm
Ex certification EEx geprüft II 2G EEx de IIC T6, II 2D IP65 T80°C
Approvals DMT 01 ATEX E 178
;