| Standards | IEC/EN 60947-5-1; EN 1088; EN 50014; EN 50018; EN 50281-1-1 |
|---|---|
| Enclosure | glass-fibre reinforced, shock-proof thermoplastic, slef-extinguishing UL 94-V0 |
| Switch insert | – |
| Protection class | IP 65 according to EN 60529 |
| Contact material | silver |
| Switching system | slow or snap action |
| Switching system | EEx 14: change-over contact with double break Zb or 2 NC contacts, galvanically separated contact bridges; EExM 14: change-over contact with single break C or Za |
| Termination | cable H05VV-F |
| Cable section | Za and Zb: 4 x 0.75mm2 Form C: 3 x 0.75mm2 |
| Uimp | 4 kV |
| Ui | 250 V |
| Ithe | Form Zb:6 A; Form C and Za:5 A |
| Ie/Ue | Form Zb:6 A/250 VAC, 0.25 A/230 VDC; Form Za:5 A/250 VAC, 0.2 A/230 VDC; Form C: 5 A/250 VAC, 0.16 A/230 VDC |
| Utilisation category | AC-15, DC-13 |
| Max. fuse rating | Form Zb:6 A gL/gG D-fuse; Form C and Za: 5 A gL/gG D-fuse |
| Ambient temperature | –20 °C … +65 °C, Form C: +60 °C, T5: +75 °C |
| Mechanical life | > 1 million operations |
| Switching frequency | 1800/h |
| Repeat accuracy of switching points | ±0.1 mm |
| Contact opening | max. 2 x 4 mm |
| Ex-marking | II 2G EEx d IIC T6, |
| Approvals | EExM 14: PTB 03 ATEX 1069 X EExM 1Ö/1S: PTB 03 ATEX 1006 X EEx 14: PTB 03 ATEX 1070 X ![]() |
| Note | Protect switch against mechanical damage! |