| Standards | IEC/EN 60947-5-2 |
|---|---|
| Enclosure | brass-nickel, PA |
| Nuts | 2, brass-nickel |
| Switching system | Namur to DIN EN 60947-5-6 |
| Termination | 2 m pre-wired cable |
| Protection class | IP 67 |
| Switching distance sn | EEx IS M12 b: 2 mm, EEx IS M12 nb: 4 mm EEx IS M18 b: 5 mm, EEx IS M12 nb: 8 mm EEx IS M30 b: 10 mm, EEx IS M30 nb: 15 mm |
| Switching distance in % | steel St 37: 100 %, stainless steel: 70 %, brass: 50 %, copper: 45 %, aluminium: 40 % |
| Input power Pi | max. 50 mW |
| Input voltage Ui | max. 12.6 VDC |
| Input current Ii | max. 15.9 mA |
| Tightening torque for the nuts | M12x1: 10 Nm, M18x1: 36 Nm, M30x1.5: 100 Nm |
| Ambient temperature | –25 °C … +75 °C |
| Ex-marking | II 1G EEx ia IIC T6, II 1D IP67 T100°C |
| Approvals | TÜV 03 ATEX 2036 |