| Standards | EN 50284; EN 50281-1-1 |
|---|---|
| Enclosure | brass-nickel, PA |
| Nuts | 2, brass-nickel |
| Switching system | 3-wire DC; 3D version: Namur per DIN EN 60947-5-6 |
| Termination | |
| Protection class | IP 67 |
| Switching distance sn | EEx IS M18 b: 5 mm, EEx IS M18 nb: 8 mm |
| Switching distance in % | |
| Input power Pi | max. 50 mW |
| Input voltage Ui | max. 12.6 VDC |
| Input current Ii | max. 15.9 mA |
| Tightening torque for the nuts | M18x1: 36 Nm |
| Ambient temperature | –25 °C … +75 °C |
| Ex-marking | II 1G EEx ia IIC T6, II 1D IP67 T100°C |
| Approvals | TÜV 06 ATEX 553179 |