// EXPLOSION PROTECTION

EEx ST 61

Technical data

Standards IEC/EN 60947-5-1; EN 1088;
EN 50014; EN 50018; EN 50281-1-1
Enclosure aluminium die-cast, enamel finish
Actuator stainless steel 1.4301
Switch insert EEx 13
Protection class IP 65 to EN 60529
Contact material silver
Switching system slow action,
NC contact with positive break Zwangsöffnung
Switching elements double-break changeover contact Zb, galvanically separated contact bridges
Termination pre-wired cable H05VV-F 4 x 0.75 mm2
Cable section 4 x 0,75 mm2
Cable length 3 m
Uimp 4 kV
Ui 250 V
Ithe 6 A
Ie/Ue 6 A/250 VAC; 0,25 A/230 VDC
Utilisation category AC-15, DC-13
Max. fuse rating 6 A gL/gG D-fuse
Positive break travel 12 mm
Positive break force -
Ambient temperature –20 °C … +65 °C
Mechanical life > 1 million operations
Ex-marking EEx geprüft II 2G EEx d IIC T6,
II 2D IP65 T80°C
Approvals PTB 03 ATEX 1068 X, referring to the switch insert

Kontaktvarianten

  Slow action   
1 NC/1 NO contact
EEx ST 61 1Ö/1S

    Actuating radius