, 1 NC contact
| Standards: | IEC/EN 60947-5-1; 95/16/EG, EN 81-1; EN 81-2; EN 1088; EN 50014; EN 50018; EN 50281-1-1 |
|---|---|
| Enclosure | glass-fibre reinforced, shock-resistant thermoplastic, |
| Actuator | stainless steel 1.4301 |
| Switch insert | – |
| Protection class | IP 65 to EN 60529 |
| Contact material | silver |
| Switching system | slow action, NC contact with positive break ![]() |
| Switching system | 1 NC contact |
| Termination | pre-wired cable H05VV-F |
| Cable section | 2 x 0.75 mm2 |
| Cable length | 1.5 m |
| Uimp | 4 kV |
| Ui | 250 V |
| Ithe | 3 A |
| Ie/Ue | 3 A/250 VAC; 0,2 A/230 VDC |
| Utilisation category | AC-15, DC-13 |
| Max. fuse rating | 3 A gL/gG D-fuse |
| Positive break travel | 3,5 mm |
| Positive break force | - |
| Ambient temperature | –20 °C … +65 °C |
| Mechanical life | > 1 million operations |
| Ex-marking | II 2G EEx d IIC T6, |
| Approvals | PTB 03 ATEX 1070 X |
| Slow action | ||
|---|---|---|
| 1 NC contact | EEx 14 AZ 1Ö |