// EXPLOSION PROTECTION

EEx 14 AZ

Technical data

Standards: IEC/EN 60947-5-1; 95/16/EG,
EN 81-1; EN 81-2; EN 1088;
EN 50014; EN 50018;
EN 50281-1-1
Enclosure glass-fibre reinforced, shock-resistant thermoplastic,
Actuator stainless steel 1.4301
Switch insert
Protection class IP 65 to EN 60529
Contact material silver
Switching system slow action, NC contact with positive break Zwangsöffnung
Switching system 1 NC contact
Termination pre-wired cable H05VV-F
Cable section 2 x 0.75 mm2
Cable length 1.5 m
Uimp 4 kV
Ui 250 V
Ithe 3 A
Ie/Ue 3 A/250 VAC; 0,2 A/230 VDC
Utilisation category AC-15, DC-13
Max. fuse rating 3 A gL/gG D-fuse
Positive break travel 3,5 mm
Positive break force -
Ambient temperature –20 °C … +65 °C
Mechanical life > 1 million operations
Ex-marking EEx geprüft II 2G EEx d IIC T6, II 2D IP65 T80°C
Approvals PTB 03 ATEX 1070 X

Kontaktvarianten

  Slow action   
1 NC contact
EEx 14 AZ 1Ö

Actuating radius