// EXPLOSION PROTECTION

EEx ZS 75 SR

Technical data

Standards IEC/EN 60947-5-1, EN 50014, EN 50018, EN 50281-1-1
Enclosure aluminium die casting, enamel finish
Cover aluminium die casting, enamel finish
Switch insert EEx 14
Protection class EEx ZS 75 SR VD: IP 65; EEx ZS 75 SR VS: IP 54 to IEC/EN 60529
Contact material silver
Switching system slow action, positive break NC contacts Zwangsöffnung
Switching elements change-over contact with double break or 2 NO/2 NC or 4 NC contacts
Connection cable H05VV-F
Cable section 4 x 0.75mm2 (incl. conductor ferrules)
Cable length 3 m
Uimp 4 kV
Ui 250 V
Ithe 6 A
Utilisation category AC-15, DC-13
Ie/Ue 6 A/250 VAC, 0,25 A/230 VDC
Max. fuse rating 6 A gL/gG D-fuse
Ambient temperature –20 °C … +65 °C, T5: +75 ºC
Mechanical life > 1 million operations
Ex certification EEx geprüft II 2G EEx d IIC T6, II 2D IP65 T80°C
Approvals PTB 06 ATEX 1067 X

Contact variants

  Slow action   
1 NC/1 NO contact
EEx ZS 75 SR 1Ö/1S
2 NC/2 NO contacts
EEx ZS 75 SR 2Ö/2S
4 NC contacts
EEx ZS 75 SR 4Ö

Features/Options

  • Indicator lamps for zone 22 for 24VDC are indicated at the end of this chapter
  • Indicator lamp position on the left side, other positions possible on request
  • Version for equipment category 3D, dust Ex zone 22 is equipped with a wiring compartment

Key release VS