// CONTROL TECHNOLOGY

Safety sensors
HS Si 4

Technical data

Standards EN ISO 13849-1;
IEC/EN 60947-5-2;
IEC/EN 60947-5-3/PDF-M*;
EN 954-1; EN 1088
Enclosure glass-fibre reinforced thermoplastic,
ultramid A3XZG5, self-extinguishing
Defined object Actuator MC 4
(order no. 05.00.8221)
Degree of protection IP 67 to IEC/EN 60529
Switching system Hall sensor, 2 channels galvanically separated, semiconductor
1 NC/1 NO or 2 NC contacts
Connection cable, 6 x AWG 26
Cable length 1 m

Safety-relevant data:
EN 954-1 Category 4 *
EN ISO 13849-1 PL e
TM 10 years
MTTFd > 100 years

Utilisation category

DC-13, DC-12
Ie/Ue 40 mA / 24 VDC
Ue 10 … 30 VDC
Ui 75 VDC
Uimp 1 kV
Residual current ≤ 6 mA per channel
Voltage drop ≤ 2.5 VDC
Switch-on/switch-off time < 1 ms
Risk time < 100 ms
Max. fuse rating < 50 mA internal reversible fuse
Switching frequency max. 1000 Hz
Degree of pollution 3
Overvoltage category II
Ambient temperature -20 °C … +70 ºC
Switching capacity:
sao 6 mm
sar 20 mm

* is only achieved in combination with a safety module

Ordering details

 
1 NC/1 NO contact
TypeOrder no.
HS Si 4 1Ö/1S-1m20460101/ Download >
2 NC contacts
TypeOrder no.
HS Si 4 2Ö-1m20470101/ Download >

Accessories

 
Actuator MC 4
TypeOrder no.
Actuator MC 4
05.00.8221 / Download >