// CONTROL TECHNOLOGY

Safety sensors
BZ 16

Technical data

Standards IEC/EN 60947-5-3; EN 954-1; EN 1088
Enclosure glass-fibre reinforced, shock-proof thermoplastic, self-extinguishing
Actuator BZ 16-B1
Protection class IP 67 or IP 69K to IEC/EN 60529
Contact material
Switching system Hall sensor
Contact types 1 NC/1NO contact or 2 NC contacts
Termination terminal space with self opening terminal for max. 2 x 1.5 mm2 (including conductor ferrules)
Cable entry 3 x M20 x 1.5
Cable length
Uimp 24 VDC +/ -15 %
Max. fuse rating 0.25 A gL/gG D-fuse
Power consumption < 4 W
Outputs
Utilisation category AC-15, DC-13
Ie/Ue 2.5 A/250 VAC, 2.5 A/24 VDC
Switching voltage max. 250 VAC
Switching current max. 4 A
Switching capacity max. 1000 VA
Max. fuse rating 4 A gL/gG D-fuse
Switching frequency max. 1 Hz
Bounce duration -
Ambient temperature 0 °C … +55 ºC
Mechanical life > 10 million operations
Electrical life
Switching time “Close” < 200 ms
Switching time “Open” < 200 ms
Switching capacity
sao 10 mm
sar 20 mm
Hysteresis sao 1 mm
Axial misalignment max. 3 mm

Kontaktvarianten

  multidirectional actuation   
1 NC/1 NO contact
BZ 16 11
2 NC contacts
BZ 16 02

Features/Options

  • Please indicate the desired actuating plane when ordering.
  • Version with higher protection class IP 69K:
    suitable for cleaning with 80°C hot water at 100-bar pressure at a distance of 100 mm from different directions

Note
The actuator is not included in the delivery of the switches.

BZ 16 IP 69K

Actuator BZ 16-B1

Actuating planes

Distance for actuation from side

Switching capacity