// CONTROL TECHNOLOGY

Position switches with safety function
ES/EM 95

Technical data

Standards IEC/EN 60947-5-1; EN 1088; BG-GS-ET-15
Class DIN EN 50 047
Enclosure glass-fibre reinforced, shock-proof thermoplastic, self-extinguishing UL 94-V0
Protection class IP 67 to IEC/EN 60529
Contact material silver
Switching elements change-over contact with double break Zb or 2 NC contacts, galvanically separated contact bridges
Switching system Zwangsöffnung IEC 60947-5-1 slow action, positive break NC contacts
Termination plug-in connector
Cable section max. 2.5 mm2 (incl. conductor ferrules)
Cable entry M 20 x 1.5
Uimp 4 kV
Ui 400 V
Ithe 6 A
Utilisation category AC-15; DC-13
Ie/Ue 6 A/400 VAC; 0,25 A/230 VDC
Max. fuse rating 6 A gL/gG D-fuse
Mechanical life > 1 million operations
Switching frequency 1800/h
Ambient temperature –20 °C … +80 ºC
Contact opening 2 x 3.5 mm
Approvals

Features/Options

  • Mechanical locking: release by means of push button
  • Mechanical locking V only possible with slow action
  • With gold-plated contacts available on request

mechanical locking

Connector M12 x 1, 4-pole