| Standards | IEC/EN 60947-5-1 |
|---|---|
| Enclosure | glass-fibre reinforced polyamide |
| Actuator | Series M permanent magnet |
| Protection class | IP 67 to EN 60529 |
| Contact material | Rhodium |
| Switching system | Reed contacts |
| Contact types | NO contact, changeover contact, changeover or bi-stable latching contact |
| Termination pre-wired cable, | pre-wired cable, PVC LiYY AWG 26 |
| Cable section | 2 x 0,14 mm2 / 3 x 0,14 mm2 |
| Cable length | 1, 2 or 5 m |
| Switching voltage | 1 S: max. 250 VDC / |
| Switching current | 1 S: max. 1 A / 1 W = max. 0,25 A |
| Switching capacity | 1 S: max. 15 W / 1 W = max. 3 W |
| Switching frequency | max. 200 Hz |
| Ambient temperature | –10 °C … +80 ºC |
| Mechanical life | 109 operations |
| Electrical life | 109 operations |
| Repeat accuracy | ± 0,02 mm |
| Resistance to vibrations | 20 g |
| actuation from side | ||
|---|---|---|
| 1 NO contact | RC 40 1S |
|
| 1 bistable contact | RC 40 1Sr |
|
| 1 change-over contact | RC 40 1W |
|
| 1 bistable change-over contact | RC 40 1Wr |