// CONTROL TECHNOLOGY

Magnetic sensors, cylindrical form
RC 23

Technical data

Standards IEC/EN 60947-5-1
Enclosure Aluminium brass, nickeled
Actuator Series M permanent magnet
Protection class IP 67; with plug-in connector IP 42/65 to EN 60529
Contact material Rhodium; -W: Tungsten
Switching system Reed contacts
Contact types NO contact or Changeover contact
Termination lead-free pre-wired cable, PVC H05VV-F
Cable section 2 x 0,5 mm2
Cable length 1, 2 or 5 m
Switching voltage max. 250 VAC/DC
Switching current 1S: 2 A; 1W: 0,5 A; -W: 1 A
Switching capacity 1S: max. 50 VA/ W;
1W: max. 15 VA/ W;
-W: max. 25 VA/ W
Switching frequency max. 200 Hz
Ambient temperature –10 °C … +80 ºC
Mechanical life 109 operations
Electrical life 109 operations
Repeat accuracy ± 0,02 mm
Resistance to vibrations 1S: 20 g, 1W: 10 g

Kontaktvarianten

  bidirectional actuation   
1 NO contact
RC 23 1S
1 change-over contact
RC 23 1W

Features/Options

  • Version for high temperatures up to +130 °C with silicon cable available

Actuator M 20 U

Merkmale/Optionen

  • Unenclosed
  • Barium ferrite
  • Ambient temperature:
    –20 °C … +80 °C

 

Actuator M 50 N U

Features/Options

  • Unenclosed
  • Barium ferrite
  • Ambient temperature:
    –20 °C … +80 °C

Actuator M 100 N U

Features/Options

  • Unenclosed
  • Barium ferrite
  • Ambient temperature:
    –20 °C … +80 °C

Actuator M 100 S

Features/Options

  • Thermoplastic enclosure,
    blue S or red N
  • Barium ferrite
  • Ambient temperature:
    –20 °C … +80 °C

Actuator M 100 N

Features/Options

  • Thermoplastic enclosure polyamide 6.6,
    blue S or red N
  • Barium ferrite
  • Ambient temperature:
    –20 °C … +80 °C

Actuator M 200 N U

Features/Options

  • Unenclosed
  • Barium ferrite
  • Ambient temperature:
    –20 °C … +80 °C

Actuator M 200 S

Features/Options

  • Thermoplastic enclosure,
    blue S or red N
  • Barium ferrite
  • Ambient temperature:
    –20 °C … +80 °C

Actuator M 200 N

Features/Options

  • Thermoplastic enclosure polyamide 6.6,
    blue S or red N
  • Barium ferrite
  • Ambient temperature:
    –20 °C … +80 °C

Actuator M 300 N U

Features/Options

  • Unenclosed
  • M 300 U: colour coding of the north pole (red point)
  • Barium ferrite
  • Ambient temperature:
    –20 °C … +80 °C

Actuator M 300 U B

Features/Options

  • Unenclosed
  • M 300 U: colour coding of the north pole (red point)
  • Barium ferrite
  • Ambient temperature:
    –20 °C … +80 °C

Actuator M 300 S

Features/Options

  • Thermoplastic enclosure,
    blue S or red N
  • Barium ferrite
  • Ambient temperature:
    –20 °C … +80 °C

Actuator M 300 N

Features/Options

  • Thermoplastic enclosure,
    blue S or red N
  • Barium ferrite
  • Ambient temperature:
    –20 °C … +80 °C

Actuator M 400 N U

Features/Options

  • Unenclosed
  • Barium ferrite
  • Ambient temperature:
    –20 °C … +80 °C

Actuator M 400 U B

Features/Options

  • Unenclosed
  • Barium ferrite
  • Ambient temperature:
    –20 °C … +80 °C

Actuator M 700 S

Features/Options

  • Thermoplastic enclosure Polyamid 6.6, blue S
  • Barium ferrite
  • Ambient temperature:
    –20 °C … +80 °C

Actuator M 700 N

Features/Options

  • Thermoplastic enclosure,
    red N
  • Barium ferrite
  • Ambient temperature:
    –20 °C … +80 °C

Actuator M 500

Features/Options

  • Thermoplastic enclosure glass-fibre reinforced polyamid
  • Barium ferrite
  • Ambient temperature:
    –20 °C … +80 °C