// CONTROL TECHNOLOGY

Magnetic safety sensors
RC Si 56

Technical data

Standards IEC/EN 60947-5-3; EN 954-1; EN 1088
Enclosure glass-fibre reinforced thermoplastic
Actuator MC 56
Protection class IP 67 to IEC/EN 60529
Contact material
Switching system Reed contacts
Contact types 1NC/1 NO contact or 2 NC contacts
Termination pre-wired cable AWG 24
Cable section 4 x 0,5 mm2
Cable length 1 m
Uimp
Power consumption
Outputs
Utilisation category
Ie/Ue
Switching voltage max. 30 VDC
Switching current max. 125 mA, with LED: 20 mA
Switching capacity max. 6 W/VA
Voltage drop at Imax 2.5 V, with LED: 3 V
Short-circuit current max. 750 mA for 50 ms, with LED: 30 mA
Max. fuse rating
Switching frequency max. 5 Hz
Ambient temperature -20 °C … +70 ºC
Mechanical life > 10 million operations
Electrical life
Switching capacity
sao 7 mm
sar 23 mm
Axial misalignment 2 mm

Kontaktvarianten

  bidirectional actuation   
1 NC/1 NO contact
RC Si 56 1Ö/1S
2 NC contacts
RC Si 56 2Ö

    Note
    The actuator is not included in the delivery of the switches.

    Actuatig magnet MC 56