// CONTROL TECHNOLOGY

Foot switches metal enclosure
GFI D

Technical data

Standards EN ISO 13849-1; IEC/EN 60947-5-1
Enclosure aluminium die-cast, enamel finish,
RAL 5011
Cover aluminium die-cast, enamel finish,
RAL 2004
Pedal aluminium die-cast, enamel finish,
RAL 5011
Connection screw terminals
Wire cross-section max. 2.5 mm²
(incl. conductor ferrules)
Cable entry M20 x 1.5
Contact material silver
Protection class IP 65 to IEC/EN 60529
Switching system slow action with double break, positive break NC contact Zwangsöffnung
Switch insert 2 x ES 40 GF
Switching element 2-step switching:
1 NC/1 NO contact
pressure point:
1 NC/1 NO contact
Actuating force approx. 240 N
B10d (10% Load) 2 million
TM 10 years
Utilisation category AC-15
Ie/Ue 6 A/400 VAC
Max. fuse rating 6 A gL/gG D-fuse
Ambient temperature –25 °C … +80 ºC
Mechanical life > 1 million operations
Approvals BRD

Ordering details

 
Slow action
1 NC/1 NO contact
TypeOrder no.
GFI 1ÖS D 1ÖSon request/ Download >