STM 295

Features/Options

  • Thermoplastic enclosure
  • Double insulated Schutzisoliert
  • Spring-to-lock or power-to-lock principle
  • Holding force 1000 N
  • Wiring compartment

Note

The actuator is not included with the switches.

Product image

 

Technical data

Standards: EN ISO 13849-1;
IEC/EN 60947-5-1; EN 1088
Enclosure glass-fibre reinforced, shock-resistant thermoplastic, self-extinguishing UL 94-V0
Switch insert STM 295
Degree of protection IP 67 to IEC/EN 60529
Contact material silver
Switching system slow action, NC contact with positive break Zwangsöffnung
Switching elements 2 NC and 2 NO contacts with positive break, galvanically separated contact bridges
Connection M3 screw clamps
Cable section max. 1.5 mm2
(incl. conductor ferrules)
Cable entries 2 x M20 x 1.5
for cable section 5 … 9 mm
B10d (10% Load) 1 million
TM max. 20 years
Uimp 4 kV
Ui 250 V
Ithe 4 A
Ie/Ue 4 A/250 VAC; 0.25 A/230 VDC
Utilisation category AC-15, DC-13
Max. fuse rating 6 A gL/gG D-fuse
Us 24 VDC
Magnet 100 % ED
Unlocking 100 % ED
Power consumption max. 47 W
Ambient temperature –20 °C … +55 °C
Mechanical life > 500.000 operations
Holding force F max. 1000 N
Approvals