HS Si 4

Features/Options

  • Thermoplastic enclosure
  • Long life
  • High shock resistance
  • Hall sensor 1 NC/1 NO or 2 NC contacts
  • Galvanically separated channels
  • With pre-wired cable
Note
  • The actuator is not included in the delivery of the switches

Product image

 

Technical data

StandardsEN ISO 13849-1;
EN 60947-5-2;
EN 60947-5-3/PDF-M*;
EN 954-1; EN 1088
Enclosureglass-fibre reinforced thermoplastic,
ultramid A3XZG5, self-extinguishing
Defined objectActuator MC 4
(order no. 05.00.8221)
Degree of protectionIP 67 to IEC/EN 60529
Switching systemHall sensor, 2 channels galvanically separated, semiconductor
1 NC/1 NO or 2 NC contacts
Connectioncable 6 x AWG 26
 
Safety-relevant data:
EN 954-1Category 4 *
EN ISO 13849-1PL e
TMmax. 20 years
MTTFd> 100 years
 
Utilisation categoryDC-13, DC-12
Ie/Ue40 mA / 24 VDC
Ue10 … 30 VDC
Ui75 VDC
Uimp1 kV
Residual current≤ 6 mA per channel
Voltage dropmax. 2.5 VDC
Switch-on/switch-off time< 1 ms
Risk time< 100 ms
Max. fuse rating< 50 mA internal reversible fuse
Switching frequencymax. 1000 Hz
Degree of pollution3
Safety classII
Ambient temperature–20 °C … +70 °C
Switching distances:
sao6 mm
sar20 mm

* is only achieved in combination with a safety module