GFS 2 VD

Features/Options

  • 2-pedal type
  • With impulse wiping contacts GFS 2 IK VD: without switching impulse when unlocking foot switch; NO contact 13-14 is converted into positive break NC contact by internal baffle after pressure point, Safety contact: 13-14 , Signalling contact: 21-22
  • Max. 4 contacts per pedal, max. 3 pedals available
  • Wiring compartment
  • Available on request with special finish in RAL colour tones

Product image

 

Technical data

StandardsEN ISO 13849-1;
EN 60947-5-1, BG-GS-ET-15
Enclosurealuminium die-cast, enamel finish, RAL 5011
Pedalglass-fibre reinforced thermoplastic
Protective shieldaluminium die-cast, enamel finish, RAL 5011
Connectionscrew terminals
Cable sectionmax. 2.5 mm²
(incl. conductor ferrules)
Cable entry1 x M25 x 1.5
Contact materialsilver
Degree of protectionIP 65 to IEC/EN 60529
Switching systemslow action with double break, positive break NC contact per EN 60947-5-1
Switch insertES 60 GF VD, ES 60 GF IK VD
Switching elements1 NO/1 NC or 2 NO/2 NC contacts per pedal
Actuating forceapprox. 240 N
B10d (10 % Load)200 000
TMmax. 20 years
Utilisation categoryAC-15
Uimp6 kV
Ui500 V
ItheGFS 2 VD: 16 A, GFS 2 IK VD: 6 A
Ie/UeGFS 2 VD: 16 A/400 VAC,
GFS 2 IK VD: 6 A/400 VAC
Contact load capacitiymax. 400 VAC,
GFS 2 VD: max. 16 A (cos φ = 1),
GFS 2 IK VD: max. 6 A (cos φ = 1)
Max. fuse ratingGFS 2 VD: 16 A gG/gN fuse,
GFS 2 IK VD: 6 A gG/gN fuse
Ambient temperature–25 °C … +80 °C
Mechanical life> 100 000 operations
ApprovalsGFS 2 VD: ,
GFS 2 IK VD: