Position switch

HS 98 with analogue output


  • With analogue output

  • Design to EN 50041

  • Wiring compartment

  • High degree of protection IP67

Technical data

Applied standards

EN 60947-5-2, EN 60947-5-7

Enclosure

aluminium die-cast, powder-coated

Degree of protection

IP67 (IEC/EN 60529)

Switching system

Hall sensor with analogue output

Linearity

2 %

Connection

Cage clamps

Cable cross-section

max. 0.08 … 2.5 mm², AWG 28 … 12

Cable entry

1 x M20 x 1.5

Over temperature protection

monitoring via μ controller + NTC

Rated operating voltage Ue

24 VDC

Rated operating voltage range UB

18 … 30 VDC

Rated output current

Q2: ≤ 100 mA short-circuit protected

Voltage drop at Ie

2 V

Attendance delay tv

< 500 ms

Short-circuit protection

internal fuse 0.375 A F

Ambient temperature

–20 °C … +60 °C

Mechanical life

> 1 million operations

Downloads

Loading...
Mounting and wiring instructions – HS 98

German, English, French, Italian, Portuguese, Russian

PDF 300 KB 25.09.2023
Please go to the relevant product pages for additional downloads.

Variants / Options

The following variants / options are available on request:

  • Further actuators
to your contact persons

Other interesting products

Alternative version with explosion protection

Ex

Corrosion-resistant version with higher degree of protection