- Home
- Accessories
- Products
- Wireless receivers and repeaters
- sWave® 868 MHz
- Wireless Receiver
RF Rx SW868-TCP/IP - Wireless Repeater
RF RxT SW868-USB - Wireless Receiver
RF Rx SW868-1W - Wireless Receiver
RF Rx SW868-2W-RS232 - Wireless Receiver
RF Rx SW868-4W - Wireless Receiver
RF Rx SW868-4S - Wireless Repeater
RF RxT SW868-1K - Wireless Repeater
RF RxT SW868-2K - sWave® 915 MHz
- Wireless Receiver
RF Rx SW915-TCP/IP - Wireless Repeater
RF RxT SW915-USB - Wireless Receiver
RF Rx SW915-1W - Wireless Receiver
RF Rx SW915-2W-RS232 - Wireless Receiver
RF Rx SW915-4W - Wireless Receiver
RF Rx SW915-4S - Wireless Repeater
RF RxT SW915-1K - Wireless Repeater
RF RxT SW915-2K - sWave® 922 MHz
- Wireless Repeater
RF RxT SW922-USB - Wireless Receiver
RF Rx SW922-4S - sWave® 2.4 GHz
- Wireless receiver
RF RxT SW2.4 - EnOcean® 868 MHz
- Wireless receiver
RF Rx EN868-TCP/IP - Wireless Receiver
RF RxT EN868-USB - Wireless Receiver
RF Rx EN868-1 - Wireless receiver
RF Rx EN868-2W - Wireless receiver
RF Rx EN868-2W-RS232 - Wireless receiver
RF Rx EN868-2W-s-RS232 - Wireless Receiver
RF Rx EN868-4W - Wireless Repeater
RF RxT EN868-230VAC
- Wireless receivers and repeaters
Wireless receiver RF Rx SW868-1W 24 VAC/DC
Wireless receivers and repeaters
Material number: 1190427(Material number old: 90590023)
In stock
Downloads
» Data sheet
PDF |
22.04.2018
» EC-Declaration of Conformity
PDF |
793 KB |
27.07.2017
» Mounting and wiring instructions
PDF |
2 MB |
27.07.2017
» STEP-File
ZIP |
181 KB |
20.03.2017
Technical data
Standards | EN 60947-5-1; EN 61000-6-2, -6-3, EN 61000-4-2, -4-20, -4-4, -4-5, -4-6; EN 60068-2-6, EN 60068-2-27; EN 301 489-1; EN 301 489-3; EN 300 220-1; EN 300 220-2 |
---|---|
Number of channels | 1 |
Mounting | DIN rail mounting |
Connection | terminals with CAGE CLAMP WAGO Series 236: 0.08 … 2.5 mm² / AWG 28-12, AWG 12: THHN, THWN, stripping length 5 … 6 mm / 0.22 in |
Degree of protection | IP 20 to IEC/EN 60529 |
Inputs | 1 wireless channel, max. 10 transmitters per channel |
Outputs | 1 change-over contact (relay) |
Rated operating current Ie | 24 VDC: max. 0.03 A; 24 VAC: max. 0.07 A |
Rated operating voltage Ue | 24 VAC/DC -15 % … +10 % |
Ie/Ue of output contacts | 6 A/250 VAC; 2 A/24 VDC |
Utilisation category | AC-15; DC-13 |
Ui | 250 VAC |
Uimp | 2.5 kV |
Frequency | 868.3 MHz |
Display | green LED: operating state, orange LED: switching conditions |
Operation cycles | approx. 12000 telegrams at repetitions/h |
Degree of pollution | 2 to IEC/EN 60664-1 |
Ambient temperature | 0 °C … +55 °C |
Storage and shipping temperature | –25 °C … +85 °C |
External antenna | always required for optimum wireless range |
Note | Inductive loads (contactors, relays etc.) are to be suppressed by suitable circuitry. |
Arrangement of receiver and switch antenna

Optimum Possible Unsuitable
mounting mounting mounting
Note
Magnetic base antennae must be mounted on a
metal plate of min. 250 x 250 mm size.